small scale incinerator

A room of post combustion of gases
oA burner of combustion of gases,
Fuel? : diesel

Manufacturer to provide  necessary information for the best of  the installation

The control panel shall have all appropriate audible and visual alarms to ensure safe operation.

This incinerator with”PYROLYTIC” combustion must possess:
? Thickness    : ≥150 mm
OA secondary injection of air to guarantee perfect oxygen content.

A control box ensuring the complete cycle of combustion.

Fan:

Incinerators Biological waste disposal system (incinerator)

Incinerator must satisfy these specifications:

–       Combustion capacity (kW) = 581 +/-10%

–       Combustion capacity (kcal/h) = 500,000 +/-10%

–       Max. . 50% water content) = 100 +/-10%

Further specifications will be supplied with the inquiry.

The incinerator shall be fully self contained.

The incinerator plant will incorporate a control panel for its operation. On the control panel we will have a visual display of the room temperatures. This visual display must control and monitor the incinerator and his performance.

Capacity of destruction in weight will be 60 Kg/h.

it ought to be able to operate not less than 10 hours/day

This incinerator must be able to destruct all combustible wastes produced by hospitals, private clinics, laboratories, institutes, etc…

Design Specification: Types A, B, C, D, and E of medical waste

“PYROLYTIC” combustion, by controlling the gasification of waste.

The incinerator must prevent the discharge of black smoke and dust that is fine, during the loadings.

It shall be able to decrease the quantity of wastes by 98%.

It shall be able to hold emission in the second burn with gasoline residence of not less than two seconds.

The incineration should be completely free from visible smoke in addition to offensive odours.

1.0The primary ignition burner shall providing ignition of the waste to 850 °C and must switch off to conserve fuel.

the principal combustion chamber shall be constructed from heavy steel plate and the device is internally lined with a complete layer of hote face refractory and higher efficiency insulation. 400 and its elevation: 8 m

The loudness of the combustion chamber at least: 1.200 L

The Dimension of the door for loading in cm : 70×70.

Burner operation should be Automatic On/Off
A regulator with digital watching for the temperature of combustion.
? Nature: 65% of Al203
?
Refractory concrete :
. Nature: 42 percent of Al203
OBurner with fuel, mono-bloc casting directing type with flat flame, lighting and security of electronic ignition, permanent venting, electromagnetic sluice gate of regulation and isolating valve.
OThe insulation of the combustion chamber ought to be composed of refractory bricks, using a high content of aluminium and insulates bricks in order to guarantee a minimum temperature on the exterior sheet metal.
OElectro-ventilator distributing the secondary atmosphere, the regulation of the air flow being completed by valves and following the control of the automatic cycle.
Control box watertight into dust, such as:

A switch circuit breaker for each engine (ventilators and burners).
OPerfectly tight doorway for the manual loading of waste. The loading should be Manual, Batch Load
OComposition of this refractory;
Electric box

The secondary combustion chamber must destroy the contaminant merchandise and must resist to high temperature(1100 °C)

Process Filtering system: Scruber to be mentionned as optional

The secondary combustion chamber must destroy the contaminant product and must resist to high temperature(1100 °C)

Process Filtering system: Scruber to be mentionned as optional