incinerators for sale

chamber and burner shall be designed to maintain a minimum combustion temperature of 760 to 870 C

 

(1400 to 1600 F). The ash-removal system shall consist of the automatic continuous removal of the ash into an ashquench

 

pit in which cooled by water and removed from conveyor.

 

Secondary combustion chamber shall be a solid-walled and -floored, horizontal, refractory-lined cylinder type

 

incinerator designed to oxidize (or burn) the organic vapors and gases. Burner and combustion air controllers shall be

 

fully automatic comprising of, as a minimum, electronic ignition and all necessary interlocks and safety devices to

 

provide safe operation. The chamber and burner shall be designed to maintain a minimum combustion temperature

 

of 930 to 1200 C (1700 to 2200 F) with a minimum gas house (or live ) time of 2.0 seconds. The ashremoval

 

system shall consist of, as a minimum, the direct manual removal to some sterile collection hopper.

 

Cyclone air filters shall be provided to remove the larger particulates. Cyclone air separators may be offered with

 

powered fans to increase the speed of the gases inside the cyclone to improve the collection efficiency for smaller

 

particles.