incineration Heating system for shedding patalogical (such as human cells or blood) as west
The weight of the west merchandise is 700 kg per month and likewise we require an isolated heater
Without fume in addition to any type of sort of damaging gas
. INCINERATOR REQUIREMENTS
# Recap Spec
1 Burning Capacity – – – – 400 kg/time and also need not to be much less than 300 kg/time. Maximum burning time require to be 6 times/day
two Smokeshaft exterior diameter – – – – 300 to 400 millimeter
3 Fan power – – – Need not to exceed 1.1 kw
4 Voltage – – – – 220V
5 Oil intake – – – Have not to exceed 14kg/h
6 Feeding door diagonal measurement (mm) – – – – Not less than 500mm 7 Incineration Temperature. (⁰ C) – – – – 800 or over 8 Exhaust
Carbon Monoxide – – – – Have to not exceed 100 mg/m3
SO2 – – Need to not exceed 400 mg/m3
HF – – – – (Hydrogen fluoride) Shouldn’t exceed 9.0 mg/m3
NO2 – – – – Shouldn’t go beyond 500 mg/m3
Smoke dirt – – – – Need to go beyond 100 mg/m3
9 Elevation of the Burner – – – – Very little less than 10m over ground level
10 Manufacturer’s Solution warranty – – – – Not less than 1 year
11 Electrical Link – – – – From closest blood circulation box using 25mm2 electric cord and additionally all applicable links and circuitry